For a better experience, please enable JavaScript in your browser before proceeding.I have an equation for the friction factor so no problem there, and I know the Reynolds number as well.
What confuses me is choosing the suitable velocity for the pressure drop equation; itexfracpLitex itexfracv22Dhitex The thickness of the orifice varies so the initial velocity corresponding to the Reynolds number surely wont be the most accurate choise for the pressure drop calculation, will it (The thickness over hydraulic diameter will vary between 0 and 10). This is not a homework question I want to approximate the pressure drop in order to validate a CFD model of the orifice. Orifice Plate Pressure Drop Calculator Upgrade Your BrowserPlease upgrade your browser or activate Google Chrome Frame to improve your experience. FCI has distinguished itself in the technical advancement of the fluid control industry through the development of standards to promote the production of higher quality, more useful products. Orifice Plate Pressure Drop Calculator Install And ManufactureOrifice flow meters are generally less expensive to install and manufacture than the other commonly used. Viscosity page. The isentropic exponent, K, is based on the specific. This is a just a warning message; all variables are computed. T(abs)0. Absolute pressure or absolute temperature was entered as. ![]() LMNO Engineering, Research, and Software, Ltd. Athens, Ohio 45701 USA Phone: (740) 707-2614 LMNOLMNOeng.com.